MODEL
DFEA
2-way, 2 stage, solenoid-operated directional poppet valve - flow 1-2
SERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-16A
X-Control, C-Poppet X-Control, H-Poppet
D-Control, C-Poppet D-Control, H-Poppet
L-Control, C-Poppet L-Control, H-Poppet
M-Control, C-Poppet M-Control, H-Poppet
T-Control, C-Poppet T-Control, H-Poppet
This solenoid controlled, 2-way, 2-position cartridge is a pilot-operated, poppet style directional valve with reverse
free flow check. It is available in either a normally open or normally closed configuration. Due to its poppet style
construction, it has extremely low leakage.
TECHNICAL DATA
Maximum Operating Pressure 350 bar
Response Time - Typical 30 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 0,7 cc/min.@350 bar
Check Cracking Pressure 3,5 bar
Switching Frequency 15000 cycles/hr
Seal kit - Cartridge Buna: 990-016-007
Seal kit - Cartridge Viton: 990-016-006
(X)CONTROL
X No Manual Override
D Twist/Lock (Dual) Manual Override
L Twist/Lock (Detent) Manual Override
M Manual Override
T Twist (Momentary) Manual Override
(C)POPPET CONFIGURATION
C Normally Closed
H Normally Open
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
COIL *
No coil
212 DIN 43650 3 pin (Hirschman), 12 VDC
224 DIN 43650 3 pin (Hirschman), 24 VDC
712 Twin Lead, 12 VDC
724 Twin Lead, 24 VDC
912 Deutsch DT04-2P, 12 VDC
924 Deutsch DT04-2P, 24 VDC
* Additional coil options are available
snhy.com/
DFEA
TECHNICAL FEATURES
The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
Valves exhibit extremely low leakage rates; less than 10 drops/min. @ 5000 psi (0,7 cc/min @ 350 bar).
This cartridge has several manual override choices, including no manual override. See the CONFIGURATION section. Please note: Manual override functionality is
not compatible with weatherized coils.
On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control
assembly has a mechanical life expectancy of approximately 7,000 cycles.
Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage
NOTES
Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
Model Code Example: DFEAXCNCONFIGURATION OPTIONS